AAD-6 ALARM ACCESS DEVICE
|  |
|
The AAD-6 Alarm Access Device
provides interfacing of two card readers,
six supervised inputs, and four outputs to provide access control at one door
with two readers or at two doors with an individual reader at each door.
All inputs and outputs are 100% user defined, such as doors and readers.
One panel can support different reader technologies, including; Proximity,
Infrared, and Barium
Ferrite. | Specifications . .
.
|

- Output voltage
for the readers is fused
- Separate high current
rectifier with fuse is provided for the strike control and/or powering active
sensor devices
- Output provided to
strikes and sensor devices as unregulated 2 amps with a DC voltage 1.5 volts,
less than the input voltage
|
|

- Single high speed serial
communication port used to communicate with the SPP-2
- Can be either single
or dual channel
- Can be either RS-232
or RS-485
communication depending on the type of
communications modules installed
- Has the ability of
being configured as either 2-wire or 4-wire with speeds of 2400, 9600, 19.2K, or
38.4K baud.
- Support for TCP/IP,
Fiber and Modem
- Dual Redundant communication
Paths
|
|
COMMUNICATION with
SPP-2
- Can be used on the SPP-2,
AMD-12/32 and the AAD-6
- Designed to be easily
interchangeable to meet communication protocols
- Can be either two
(two-wire) half duplex or one (four-wire) full duplex port
- Two-wire configuration
can be used for redundancy on both the RS-232 and the RS-485
modules
- The RS-485 module can
be used to extend communications cable to a maximum length of 4000 feet from the
SPP-2
- Port programming
determined in the device
configuration menu at Host
- Built-in line terminators for
installation convenience
| 
|
POWER REQUIREMENTS: |
Without Battery |
|
|
|
AC input: |
16 VAC, 750 mA RMS |
|
|
DC input: |
12 VDC, 500 mA or |
|
|
|
24 VDC, 500 mA |
|
|
With Battery |
|
|
|
AC input: |
16 VAC, 1.2A RMS |
|
|
DC input: |
24 VDC, 800 mA |
|
PROTECTIVE FUSE: |
0.5 Amp auto
resetting |
|
BATTERY FOR
UPS: |
Capacity: |
12 VDC for 6 to 10 Ah |
|
|
Physical size: |
8" (203 mm) L x 3.9" W (99 mm) x 4" (102 mm), max. for SDI
field cabinet (P/N 34-094-01) |
|
BACKUP TIME: |
Typical For 6 Ah Battery |
|
|
Controller only, 72
hours |
|
|
With readers @ 100 mA, 48
hours |
|
RELAY CONTACTS: |
Form C, 5 amps at 30
VDC |
|
|
Form C, 3 amps at 120/220 VAC,
Resistive |
|
Card reader sourcing: |
300 mA total
max |
|
AC rectification, Strike
sourcing: |
2 Amps at 24 VAC
max |
|
Solid state outputs: |
Open collector, 100 mA at 24
VDC |
|
COMMUNICATION PORT: |
RS-485/RS-232, module
selectable |
|
|
CABLE
REQUIREMENTS: |
RS-485 (4-wire): 2 twisted pair, shielded
120 ohm, Belden 9842 (or equivalent); 4000 feet (1219 m)
maximum |
|
|
|
RS-485 (2-wire): 1 twisted pair, shielded
120 ohm, Belden 9841 (or equivalent); 4000 feet (1219 m)
maximum. |
|
|
|
RS-232 (4-wire): 5 conductor, shielded,
Belden 9610 (or equivalent); 50 feet (15 m)
maximum |
|
|
|
RS-232 (2-wire): 3 conductor, shielded,
Belden 9608 (or equivalent); 50 feet (15 m)
maximum |
|
|
|
Power Input: |
1 twisted pair, 18 AWG |
|
|
|
Power Fault Input: |
1 twisted pair, 24 AWG |
|
|
|
Cabinet Tamper Input: |
1 twisted pair, 24 AWG |
|
OPERATING
ENVIRONMENT: |
0 to 70 ºC,
operating |
|
|
-55 to +85 ºC,
storage |
|
|
0-95% RH,
non-condensing |
|
DIMENSIONS: |
7.5 in (L) |
6.0 in (W) |
1.5 in (H) |
|
|
(191 mm) |
(152 mm) |