Mobile
Home > Products > SpectrumLX > Hardware > SPP-2

                                             

SPP-2
STANDALONE PROCESSOR PANEL

The SPP-2 Stand Alone Processor Panel provides real time control and processing for access control, alarm reporting and remote control operation in the security environment utilizing Dynamic Allocation.  
Dynamic Allocation allows for instant reconfiguration at any time. Change and customize the operating environment for the system on the fly according to your needs at that moment. The board is designed to be ideal for the replacement or upgrade of a system without requiring the change of existing sensor devices.

Specifications . . .



  • Built-in power supply/charger
  • High speed 32 bit microprocessor (64 bit internal)
  • 2 serial ports (4 channels up to 38.4K baud)
  • 512K static RAM standard (up to 2 Mb)
  • Lithium battery back-up for access database and events
  • 8 dip switches for configuration options
  • 3 self-diagnostic status LED's
  • RS-232 and/or RS-485 communication
  • Unique address for Host Identification
  • AC or DC operation
    • 12 VDC to 24 VDC
    • 16 VAC nominal
  • 2 non-supervised inputs (cabinet tamper and power fault)

  • 1Mb of static RAM (expandable up to 2 Mb)
  • With 2 Mb of RAM, the SPP-2 will support 444,000 cardholders (7,500 standard)

  • 2 high-speed serial communication ports 
    • Port one as primary Host communication port can be a single or dual channel to the Host
    • Port two communicates with AAD's, AMD's, MR-52’s and/or the OMD's
  • Ports can be configured for either RS-232 or RS-485 communication
  • Can be configured as either 2-wire or 4-wire with speeds from 2400 up to 38.4K baud
  • Support for TCP/IP, Fiber and Modem
  • Dual Redundant communication paths
COMMUNICATION with SPP’s, AAD’s and AMD’s
  • Communication modules can be used on the SPP-2, AAD-6, and the AMD-12/32
  • Modules easily interchangeable to meet communication protocols
  • Modules can operate as either two (two-wire) half duplex or one (four-wire) full duplex port
    • Two-wire configuration can be used for redundancy on both RS-232 and RS-485 modules
  • RS-485 module extends communications cable to a max length of 8000 feet (2-4000 foot (1219 m) runs)
  • Port programming is by device configuration menu at the Host
  • RS-485 module has built in line terminators for installation convenience
  • Dual Redundant communication paths to the host and to the lower AAD’s, AMD’s, and OMD’s.

POWER REQUIREMENTS:

Without Battery

AC input:            16 VAC, 250 mA RMS

DC input:           12 VDC, 350 mA or

                            24 VDC, 200 mA

With Battery

AC input:  16VAC, 1 A RMS

DC input:  24VDC, 750 mA

PROTECTIVE FUSE:

Built-in auto resetting

Battery for UPS:

Memory:

3 VDC Lithium battery, P/N BR-2325 or equivalent.

Backup Time:  6 months without power, typical.

BACKUP TIME:

24 hours, typical.

COMMUNICATION PORTS:

Ports 1 and 2:

RS-485/RS-232, module selectable

CABLE REQUIREMENTS:

RS-485 (4-wire):  2 twisted pair, shielded 120 ohm, C4842A General Cable (or equivalent); 4000 feet (1219 m) maximum

RS-485 (2-wire):  1 twisted pair, shielded 120 ohm, C4841A General Cable (or equivalent); 4000 feet (1219 m) maximum.

RS-232 (4-wire):  5 conductor, shielded, Belden 9610 (or equivalent); 50 feet (15 m) maximum

RS-232 (2-wire):  3 conductor, shielded, Belden 9608 (or equivalent); 50 feet (15 m) maximum

Power Input:

1 twisted pair, 18 AWG

Power Fault Input:

1 twisted pair, 24 AWG

Cabinet Tamper Input:

1 twisted pair, 24 AWG

OPERATING ENVIRONMENT:

0 to +70 degree C, operating

-55 to +85 degree C, storage

0-95% RH, non-condensing

DIMENSIONS:

7.5 in (L)            6.0 in (W)             1.5 in (H)

(191 mm)           (152 mm)             (38 mm)

Go to top of page

 |   |   |   |   |   |   |