SPP-2 STANDALONE PROCESSOR PANEL
|  |
The SPP-2 Stand Alone Processor Panel
provides real time control and processing for access control, alarm
reporting and remote control operation in the security environment
utilizing Dynamic Allocation. Dynamic Allocation allows for
instant reconfiguration at any time. Change and customize the operating
environment for the system on the fly according to your needs at that
moment. The board is designed to be ideal for the replacement or
upgrade of a system without requiring the change of existing sensor
devices.Specifications . . . |

- Built-in power
supply/charger
- High speed 32 bit
microprocessor (64 bit internal)
- 2 serial ports (4
channels up to 38.4K baud)
- 512K static RAM
standard (up to 2 Mb)
- Lithium battery
back-up for access database and events
- 8 dip switches for
configuration options
- 3 self-diagnostic
status LED's
- RS-232 and/or RS-485
communication
- Unique address for
Host Identification
- AC or DC
operation
- 12 VDC to 24
VDC
- 16 VAC
nominal
- 2 non-supervised
inputs (cabinet tamper and power fault)
|

- 1Mb of static RAM
(expandable up to 2 Mb)
- With 2 Mb of RAM, the
SPP-2 will support 444,000 cardholders (7,500 standard)

- 2 high-speed serial
communication ports
- Port one as primary
Host communication port can be a single or dual channel to the Host
- Port two communicates
with AAD's, AMD's, MR-52’s and/or the OMD's
- Ports can be
configured for either RS-232 or RS-485 communication
- Can be configured as
either 2-wire or 4-wire with speeds from 2400 up to 38.4K baud
- Support for TCP/IP,
Fiber and Modem
- Dual Redundant
communication paths
|
COMMUNICATION
with SPP’s, AAD’s and AMD’s
- Communication modules
can be used on the SPP-2, AAD-6, and the AMD-12/32
- Modules easily
interchangeable to meet communication protocols
- Modules can operate as
either two (two-wire) half duplex or one (four-wire) full duplex port
- Two-wire configuration
can be used for redundancy on both RS-232 and RS-485 modules
- RS-485 module extends
communications cable to a max length of 8000 feet (2-4000 foot (1219 m) runs)
- Port programming is by
device configuration menu at the Host
- RS-485 module has
built in line terminators for installation convenience
- Dual Redundant
communication paths to the host and to the lower AAD’s, AMD’s, and
OMD’s.
| 
|
POWER
REQUIREMENTS: |
Without
Battery |
|
AC input:
16 VAC, 250 mA RMS |
|
DC input:
12 VDC, 350 mA or |
|
24 VDC, 200 mA |
|
|
|
With
Battery |
|
AC input:
16VAC, 1 A RMS |
|
DC input:
24VDC, 750 mA |
|
PROTECTIVE
FUSE: |
Built-in auto
resetting |
|
|
|
Battery
for UPS: |
|
|
Memory: |
3 VDC
Lithium battery, P/N BR-2325 or
equivalent. |
|
Backup Time: 6
months without power, typical. |
|
|
|
BACKUP
TIME: |
24
hours, typical. |
|
|
|
COMMUNICATION
PORTS: |
|
|
Ports 1 and 2: |
RS-485/RS-232, module
selectable |
|
|
|
CABLE
REQUIREMENTS: |
RS-485 (4-wire):
2 twisted pair, shielded 120 ohm, C4842A General Cable (or equivalent);
4000 feet (1219 m) maximum |
|
|
|
RS-485 (2-wire):
1 twisted pair, shielded 120 ohm, C4841A General Cable (or equivalent);
4000 feet (1219 m) maximum. |
|
|
|
RS-232 (4-wire):
5 conductor, shielded, Belden 9610 (or equivalent); 50 feet (15 m)
maximum |
|
|
|
RS-232 (2-wire):
3 conductor, shielded, Belden 9608 (or equivalent); 50 feet (15 m)
maximum |
|
|
|
Power
Input: |
1
twisted pair, 18 AWG |
|
Power Fault
Input: |
1
twisted pair, 24 AWG |
|
Cabinet Tamper
Input: |
1
twisted pair, 24 AWG |
|
|
|
OPERATING
ENVIRONMENT: |
0 to
+70 degree C, operating |
|
-55 to +85 degree C,
storage |
|
0-95%
RH, non-condensing |
|
|
|
DIMENSIONS: |
7.5 in
(L) 6.0 in (W) 1.5 in
(H) |
|
(191 mm)
(152 mm) (38
mm) | Go to top of page
 |
 |
|